Digital I/O
Name Start Address Type Access
FIO#(0:7) 2000 UINT16 R/W
EIO#(0:7) 2008 UINT16 R/W
CIO#(0:3) 2016 UINT16 R/W
MIO#(0:2) 2020 UINT16 R/W
FIO#(0:7)
- Starting Address: 2000
Read or set the state of 1 bit of digital I/O. Also configures the direction to input or output. Read 0=Low AND 1=High. Write 0=Low AND 1=High.
  • Data type: UINT16  (type index = 0)
  • Readable and writable
  • This register may be streamed
Expanded Names Addresses
FIO0, FIO1, FIO2, FIO3, FIO4, FIO5, FIO6, FIO7 Show All 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007 Show All
EIO#(0:7)
- Starting Address: 2008
Read or set the state of 1 bit of digital I/O. Also configures the direction to input or output. Read 0=Low AND 1=High. Write 0=Low AND 1=High.
  • Data type: UINT16  (type index = 0)
  • Readable and writable
  • This register may be streamed
Expanded Names Addresses
EIO0, EIO1, EIO2, EIO3, EIO4, EIO5, EIO6, EIO7 Show All 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015 Show All
CIO#(0:3)
- Starting Address: 2016
Read or set the state of 1 bit of digital I/O. Also configures the direction to input or output. Read 0=Low AND 1=High. Write 0=Low AND 1=High.
  • Data type: UINT16  (type index = 0)
  • Readable and writable
  • This register may be streamed
Expanded Names Addresses
CIO0, CIO1, CIO2, CIO3 Show All 2016, 2017, 2018, 2019 Show All
MIO#(0:2)
- Starting Address: 2020
Read or set the state of 1 bit of digital I/O. Also configures the direction to input or output. Read 0=Low AND 1=High. Write 0=Low AND 1=High.
  • Data type: UINT16  (type index = 0)
  • Readable and writable
  • This register may be streamed
Expanded Names Addresses
MIO0, MIO1, MIO2 2020, 2021, 2022